java.lang.Object
net.i2p.router.web.FormHandler
net.i2p.router.web.TuningFormHandler

public class TuningFormHandlerextends FormHandler
Form handler for the transport tuning page. Persists min/max/step ranges to autotune.config without restart.
  • Field Details

    • HAS_RANGE

      private static final int HAS_RANGE
      Tunable accepts Min/Max/Step range fields.
      See Also:
    • HAS_DEFAULT

      private static final int HAS_DEFAULT
      Tunable accepts a Default field.
      See Also:
    • HAS_OVERRIDE

      private static final int HAS_OVERRIDE
      Tunable accepts an Override (auto/manual) field.
      See Also:
    • TUNED

      private static final List<TuningFormHandler.Tunable> TUNED
      The properties the tuner page manages.
    • _formValues

      private final Map<String,String> _formValues
      Form field values submitted via jsp:setProperty, keyed by field name.
  • Constructor Details

    • TuningFormHandler

      public TuningFormHandler()
      Construct a handler for one tuning-page submission; submitted field values arrive through the setters below and are applied by processForm().
  • Method Details

    • setAckFrequencyDefault

      public void setAckFrequencyDefault(String v)
      Record the Default control for the ACK_FREQUENCY Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField(Map, String, String, String)
    • setAckFrequencyMax

      public void setAckFrequencyMax(String v)
      Record the Max control for the ACK_FREQUENCY Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setAckFrequencyMin

      public void setAckFrequencyMin(String v)
      Record the Min control for the ACK_FREQUENCY Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setAckFrequencyOverride

      public void setAckFrequencyOverride(String v)
      Record the Override control for the ACK_FREQUENCY Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setAckFrequencyStep

      public void setAckFrequencyStep(String v)
      Record the Step control for the ACK_FREQUENCY Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setBuildFirstHopTimeoutDefault

      public void setBuildFirstHopTimeoutDefault(String v)
      Record the Default control for the i2p.tunnel.build.firstHopTimeout Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setBuildFirstHopTimeoutMax

      public void setBuildFirstHopTimeoutMax(String v)
      Record the Max control for the i2p.tunnel.build.firstHopTimeout Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setBuildFirstHopTimeoutMin

      public void setBuildFirstHopTimeoutMin(String v)
      Record the Min control for the i2p.tunnel.build.firstHopTimeout Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setBuildFirstHopTimeoutOverride

      public void setBuildFirstHopTimeoutOverride(String v)
      Record the Override control for the i2p.tunnel.build.firstHopTimeout Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setBuildFirstHopTimeoutStep

      public void setBuildFirstHopTimeoutStep(String v)
      Record the Step control for the i2p.tunnel.build.firstHopTimeout Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setBuildHandlerMaxQueueDefault

      public void setBuildHandlerMaxQueueDefault(String v)
      Record the Default control for the router.buildHandlerMaxQueue Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setBuildHandlerMaxQueueMax

      public void setBuildHandlerMaxQueueMax(String v)
      Record the Max control for the router.buildHandlerMaxQueue Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setBuildHandlerMaxQueueMin

      public void setBuildHandlerMaxQueueMin(String v)
      Record the Min control for the router.buildHandlerMaxQueue Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setBuildHandlerMaxQueueOverride

      public void setBuildHandlerMaxQueueOverride(String v)
      Record the Override control for the router.buildHandlerMaxQueue Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setBuildHandlerMaxQueueStep

      public void setBuildHandlerMaxQueueStep(String v)
      Record the Step control for the router.buildHandlerMaxQueue Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setBuildRequestTimeoutDefault

      public void setBuildRequestTimeoutDefault(String v)
      Record the Default control for the i2p.tunnel.build.requestTimeout Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setBuildRequestTimeoutMax

      public void setBuildRequestTimeoutMax(String v)
      Record the Max control for the i2p.tunnel.build.requestTimeout Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setBuildRequestTimeoutMin

      public void setBuildRequestTimeoutMin(String v)
      Record the Min control for the i2p.tunnel.build.requestTimeout Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setBuildRequestTimeoutOverride

      public void setBuildRequestTimeoutOverride(String v)
      Record the Override control for the i2p.tunnel.build.requestTimeout Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setBuildRequestTimeoutStep

      public void setBuildRequestTimeoutStep(String v)
      Record the Step control for the i2p.tunnel.build.requestTimeout Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setCodelIntervalDefault

      public void setCodelIntervalDefault(String v)
      Record the Default control for the CODEL_INTERVAL Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setCodelIntervalMax

      public void setCodelIntervalMax(String v)
      Record the Max control for the CODEL_INTERVAL Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setCodelIntervalMin

      public void setCodelIntervalMin(String v)
      Record the Min control for the CODEL_INTERVAL Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setCodelIntervalOverride

      public void setCodelIntervalOverride(String v)
      Record the Override control for the CODEL_INTERVAL Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setCodelIntervalStep

      public void setCodelIntervalStep(String v)
      Record the Step control for the CODEL_INTERVAL Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setCodelTargetDefault

      public void setCodelTargetDefault(String v)
      Record the Default control for the CODEL_TARGET Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setCodelTargetMax

      public void setCodelTargetMax(String v)
      Record the Max control for the CODEL_TARGET Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setCodelTargetMin

      public void setCodelTargetMin(String v)
      Record the Min control for the CODEL_TARGET Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setCodelTargetOverride

      public void setCodelTargetOverride(String v)
      Record the Override control for the CODEL_TARGET Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setCodelTargetStep

      public void setCodelTargetStep(String v)
      Record the Step control for the CODEL_TARGET Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setCongestionAvoidanceGrowthDefault

      public void setCongestionAvoidanceGrowthDefault(String v)
      Record the Default control for the i2p.streaming.congestionAvoidanceGrowthRateFactor Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setCongestionAvoidanceGrowthOverride

      public void setCongestionAvoidanceGrowthOverride(String v)
      Record the Override control for the i2p.streaming.congestionAvoidanceGrowthRateFactor Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setDataMessageTimeoutDefault

      public void setDataMessageTimeoutDefault(String v)
      Record the Default control for the DATA_MESSAGE_TIMEOUT Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setDataMessageTimeoutMax

      public void setDataMessageTimeoutMax(String v)
      Record the Max control for the DATA_MESSAGE_TIMEOUT Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setDataMessageTimeoutMin

      public void setDataMessageTimeoutMin(String v)
      Record the Min control for the DATA_MESSAGE_TIMEOUT Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setDataMessageTimeoutOverride

      public void setDataMessageTimeoutOverride(String v)
      Record the Override control for the DATA_MESSAGE_TIMEOUT Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setDataMessageTimeoutStep

      public void setDataMessageTimeoutStep(String v)
      Record the Step control for the DATA_MESSAGE_TIMEOUT Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setEdhPrecalcMinDefault

      public void setEdhPrecalcMinDefault(String v)
      Record the Default control for the crypto.edh.precalcMin Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setEdhPrecalcMinMax

      public void setEdhPrecalcMinMax(String v)
      Record the Max control for the crypto.edh.precalcMin Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setEdhPrecalcMinMin

      public void setEdhPrecalcMinMin(String v)
      Record the Min control for the crypto.edh.precalcMin Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setEdhPrecalcMinOverride

      public void setEdhPrecalcMinOverride(String v)
      Record the Override control for the crypto.edh.precalcMin Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setEdhPrecalcMinStep

      public void setEdhPrecalcMinStep(String v)
      Record the Step control for the crypto.edh.precalcMin Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setGoodDeficitThrottleDefault

      public void setGoodDeficitThrottleDefault(String v)
      Record the Default control for the i2p.tunnel.goodDeficitThrottle Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setGoodDeficitThrottleMax

      public void setGoodDeficitThrottleMax(String v)
      Record the Max control for the i2p.tunnel.goodDeficitThrottle Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setGoodDeficitThrottleMin

      public void setGoodDeficitThrottleMin(String v)
      Record the Min control for the i2p.tunnel.goodDeficitThrottle Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setGoodDeficitThrottleOverride

      public void setGoodDeficitThrottleOverride(String v)
      Record the Override control for the i2p.tunnel.goodDeficitThrottle Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setGoodDeficitThrottleStep

      public void setGoodDeficitThrottleStep(String v)
      Record the Step control for the i2p.tunnel.goodDeficitThrottle Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setIbEstablishTimeDefault

      public void setIbEstablishTimeDefault(String v)
      Record the Default control for the MAX_IB_ESTABLISH_TIME Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setIbEstablishTimeMax

      public void setIbEstablishTimeMax(String v)
      Record the Max control for the MAX_IB_ESTABLISH_TIME Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setIbEstablishTimeMin

      public void setIbEstablishTimeMin(String v)
      Record the Min control for the MAX_IB_ESTABLISH_TIME Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setIbEstablishTimeOverride

      public void setIbEstablishTimeOverride(String v)
      Record the Override control for the MAX_IB_ESTABLISH_TIME Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setIbEstablishTimeStep

      public void setIbEstablishTimeStep(String v)
      Record the Step control for the MAX_IB_ESTABLISH_TIME Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setIbMsgsPerPumpDefault

      public void setIbMsgsPerPumpDefault(String v)
      Record the Default control for the MAX_IB_MSGS_PER_PUMP Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setIbMsgsPerPumpMax

      public void setIbMsgsPerPumpMax(String v)
      Record the Max control for the MAX_IB_MSGS_PER_PUMP Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setIbMsgsPerPumpMin

      public void setIbMsgsPerPumpMin(String v)
      Record the Min control for the MAX_IB_MSGS_PER_PUMP Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setIbMsgsPerPumpOverride

      public void setIbMsgsPerPumpOverride(String v)
      Record the Override control for the MAX_IB_MSGS_PER_PUMP Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setIbMsgsPerPumpStep

      public void setIbMsgsPerPumpStep(String v)
      Record the Step control for the MAX_IB_MSGS_PER_PUMP Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setImmediateAckDelayDefault

      public void setImmediateAckDelayDefault(String v)
      Record the Default control for the i2p.streaming.immediateAckDelay Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setImmediateAckDelayMax

      public void setImmediateAckDelayMax(String v)
      Record the Max control for the i2p.streaming.immediateAckDelay Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setImmediateAckDelayMin

      public void setImmediateAckDelayMin(String v)
      Record the Min control for the i2p.streaming.immediateAckDelay Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setImmediateAckDelayOverride

      public void setImmediateAckDelayOverride(String v)
      Record the Override control for the i2p.streaming.immediateAckDelay Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setImmediateAckDelayStep

      public void setImmediateAckDelayStep(String v)
      Record the Step control for the i2p.streaming.immediateAckDelay Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setInitialAckDelayDefault

      public void setInitialAckDelayDefault(String v)
      Record the Default control for the INITIAL_ACK_DELAY Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setInitialAckDelayMax

      public void setInitialAckDelayMax(String v)
      Record the Max control for the INITIAL_ACK_DELAY Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setInitialAckDelayMin

      public void setInitialAckDelayMin(String v)
      Record the Min control for the INITIAL_ACK_DELAY Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setInitialAckDelayOverride

      public void setInitialAckDelayOverride(String v)
      Record the Override control for the INITIAL_ACK_DELAY Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setInitialAckDelayStep

      public void setInitialAckDelayStep(String v)
      Record the Step control for the INITIAL_ACK_DELAY Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setInitialResendDelayDefault

      public void setInitialResendDelayDefault(String v)
      Record the Default control for the i2p.streaming.initialResendDelay Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setInitialResendDelayMax

      public void setInitialResendDelayMax(String v)
      Record the Max control for the i2p.streaming.initialResendDelay Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setInitialResendDelayMin

      public void setInitialResendDelayMin(String v)
      Record the Min control for the i2p.streaming.initialResendDelay Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setInitialResendDelayOverride

      public void setInitialResendDelayOverride(String v)
      Record the Override control for the i2p.streaming.initialResendDelay Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setInitialResendDelayStep

      public void setInitialResendDelayStep(String v)
      Record the Step control for the i2p.streaming.initialResendDelay Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setInitialRTODefault

      public void setInitialRTODefault(String v)
      Record the Default control for the INITIAL_RTO Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setInitialRTOMax

      public void setInitialRTOMax(String v)
      Record the Max control for the INITIAL_RTO Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setInitialRTOMin

      public void setInitialRTOMin(String v)
      Record the Min control for the INITIAL_RTO Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setInitialRTOOverride

      public void setInitialRTOOverride(String v)
      Record the Override control for the INITIAL_RTO Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setInitialRTOStep

      public void setInitialRTOStep(String v)
      Record the Step control for the INITIAL_RTO Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setInitialWindowSizeDefault

      public void setInitialWindowSizeDefault(String v)
      Record the Default control for the INITIAL_WINDOW_SIZE Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setInitialWindowSizeMax

      public void setInitialWindowSizeMax(String v)
      Record the Max control for the INITIAL_WINDOW_SIZE Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setInitialWindowSizeMin

      public void setInitialWindowSizeMin(String v)
      Record the Min control for the INITIAL_WINDOW_SIZE Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setInitialWindowSizeOverride

      public void setInitialWindowSizeOverride(String v)
      Record the Override control for the INITIAL_WINDOW_SIZE Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setInitialWindowSizeStep

      public void setInitialWindowSizeStep(String v)
      Record the Step control for the INITIAL_WINDOW_SIZE Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxConcurrentEstablishDefault

      public void setMaxConcurrentEstablishDefault(String v)
      Record the Default control for the i2np.udp.maxConcurrentEstablish Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxConcurrentEstablishMax

      public void setMaxConcurrentEstablishMax(String v)
      Record the Max control for the i2np.udp.maxConcurrentEstablish Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxConcurrentEstablishMin

      public void setMaxConcurrentEstablishMin(String v)
      Record the Min control for the i2np.udp.maxConcurrentEstablish Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxConcurrentEstablishOverride

      public void setMaxConcurrentEstablishOverride(String v)
      Record the Override control for the i2np.udp.maxConcurrentEstablish Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxConcurrentEstablishStep

      public void setMaxConcurrentEstablishStep(String v)
      Record the Step control for the i2np.udp.maxConcurrentEstablish Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxFastPeersDefault

      public void setMaxFastPeersDefault(String v)
      Record the Default control for the profileOrganizer.maxFastPeers Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxFastPeersMax

      public void setMaxFastPeersMax(String v)
      Record the Max control for the profileOrganizer.maxFastPeers Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxFastPeersMin

      public void setMaxFastPeersMin(String v)
      Record the Min control for the profileOrganizer.maxFastPeers Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxFastPeersStep

      public void setMaxFastPeersStep(String v)
      Record the Step control for the profileOrganizer.maxFastPeers Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxHighCapPeersDefault

      public void setMaxHighCapPeersDefault(String v)
      Record the Default control for the profileOrganizer.maxHighCapacityPeers Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxHighCapPeersMax

      public void setMaxHighCapPeersMax(String v)
      Record the Max control for the profileOrganizer.maxHighCapacityPeers Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxHighCapPeersMin

      public void setMaxHighCapPeersMin(String v)
      Record the Min control for the profileOrganizer.maxHighCapacityPeers Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxHighCapPeersStep

      public void setMaxHighCapPeersStep(String v)
      Record the Step control for the profileOrganizer.maxHighCapacityPeers Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxInboundBufferDefault

      public void setMaxInboundBufferDefault(String v)
      Record the Default control for the i2p.streaming.maxInboundBuffer Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxInboundBufferMax

      public void setMaxInboundBufferMax(String v)
      Record the Max control for the i2p.streaming.maxInboundBuffer Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxInboundBufferMin

      public void setMaxInboundBufferMin(String v)
      Record the Min control for the i2p.streaming.maxInboundBuffer Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxInboundBufferOverride

      public void setMaxInboundBufferOverride(String v)
      Record the Override control for the i2p.streaming.maxInboundBuffer Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxInboundBufferStep

      public void setMaxInboundBufferStep(String v)
      Record the Step control for the i2p.streaming.maxInboundBuffer Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxStreamsDefault

      public void setMaxStreamsDefault(String v)
      Record the Default control for the MAX_STREAMS Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxStreamsMax

      public void setMaxStreamsMax(String v)
      Record the Max control for the MAX_STREAMS Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxStreamsMin

      public void setMaxStreamsMin(String v)
      Record the Min control for the MAX_STREAMS Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxStreamsOverride

      public void setMaxStreamsOverride(String v)
      Record the Override control for the MAX_STREAMS Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxStreamsStep

      public void setMaxStreamsStep(String v)
      Record the Step control for the MAX_STREAMS Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxParticipatingTunnelsDefault

      public void setMaxParticipatingTunnelsDefault(String v)
      Record the Default control for the router.maxParticipatingTunnels Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxParticipatingTunnelsMax

      public void setMaxParticipatingTunnelsMax(String v)
      Record the Max control for the router.maxParticipatingTunnels Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxParticipatingTunnelsMin

      public void setMaxParticipatingTunnelsMin(String v)
      Record the Min control for the router.maxParticipatingTunnels Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxParticipatingTunnelsOverride

      public void setMaxParticipatingTunnelsOverride(String v)
      Record the Override control for the router.maxParticipatingTunnels Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxParticipatingTunnelsStep

      public void setMaxParticipatingTunnelsStep(String v)
      Record the Step control for the router.maxParticipatingTunnels Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxProfilesDefault

      public void setMaxProfilesDefault(String v)
      Record the Default control for the profileOrganizer.maxProfiles Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxProfilesMax

      public void setMaxProfilesMax(String v)
      Record the Max control for the profileOrganizer.maxProfiles Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxProfilesMin

      public void setMaxProfilesMin(String v)
      Record the Min control for the profileOrganizer.maxProfiles Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxProfilesOverride

      public void setMaxProfilesOverride(String v)
      Record the Override control for the profileOrganizer.maxProfiles Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxProfilesStep

      public void setMaxProfilesStep(String v)
      Record the Step control for the profileOrganizer.maxProfiles Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxResendDelayDefault

      public void setMaxResendDelayDefault(String v)
      Record the Default control for the i2p.streaming.maxResendDelay Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxResendDelayMax

      public void setMaxResendDelayMax(String v)
      Record the Max control for the i2p.streaming.maxResendDelay Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxResendDelayMin

      public void setMaxResendDelayMin(String v)
      Record the Min control for the i2p.streaming.maxResendDelay Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxResendDelayOverride

      public void setMaxResendDelayOverride(String v)
      Record the Override control for the i2p.streaming.maxResendDelay Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxResendDelayStep

      public void setMaxResendDelayStep(String v)
      Record the Step control for the i2p.streaming.maxResendDelay Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxRetransmissionsDefault

      public void setMaxRetransmissionsDefault(String v)
      Record the Default control for the i2p.streaming.maxRetransmissions Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxRetransmissionsMax

      public void setMaxRetransmissionsMax(String v)
      Record the Max control for the i2p.streaming.maxRetransmissions Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxRetransmissionsMin

      public void setMaxRetransmissionsMin(String v)
      Record the Min control for the i2p.streaming.maxRetransmissions Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxRetransmissionsOverride

      public void setMaxRetransmissionsOverride(String v)
      Record the Override control for the i2p.streaming.maxRetransmissions Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxRetransmissionsStep

      public void setMaxRetransmissionsStep(String v)
      Record the Step control for the i2p.streaming.maxRetransmissions Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxRTODefault

      public void setMaxRTODefault(String v)
      Record the Default control for the i2p.streaming.maxRTO Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxRTOMax

      public void setMaxRTOMax(String v)
      Record the Max control for the i2p.streaming.maxRTO Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxRTOMin

      public void setMaxRTOMin(String v)
      Record the Min control for the i2p.streaming.maxRTO Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxRTOOverride

      public void setMaxRTOOverride(String v)
      Record the Override control for the i2p.streaming.maxRTO Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxRTOStep

      public void setMaxRTOStep(String v)
      Record the Step control for the i2p.streaming.maxRTO Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxRttDefault

      public void setMaxRttDefault(String v)
      Record the Default control for the i2p.streaming.maxRtt Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxRttMax

      public void setMaxRttMax(String v)
      Record the Max control for the i2p.streaming.maxRtt Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxRttMin

      public void setMaxRttMin(String v)
      Record the Min control for the i2p.streaming.maxRtt Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxRttOverride

      public void setMaxRttOverride(String v)
      Record the Override control for the i2p.streaming.maxRtt Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxRttStep

      public void setMaxRttStep(String v)
      Record the Step control for the i2p.streaming.maxRtt Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxSlowStartWindowDefault

      public void setMaxSlowStartWindowDefault(String v)
      Record the Default control for the i2p.streaming.maxSlowStartWindow Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxSlowStartWindowMax

      public void setMaxSlowStartWindowMax(String v)
      Record the Max control for the i2p.streaming.maxSlowStartWindow Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxSlowStartWindowMin

      public void setMaxSlowStartWindowMin(String v)
      Record the Min control for the i2p.streaming.maxSlowStartWindow Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxSlowStartWindowOverride

      public void setMaxSlowStartWindowOverride(String v)
      Record the Override control for the i2p.streaming.maxSlowStartWindow Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxSlowStartWindowStep

      public void setMaxSlowStartWindowStep(String v)
      Record the Step control for the i2p.streaming.maxSlowStartWindow Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMinFastPeersDefault

      public void setMinFastPeersDefault(String v)
      Record the Default control for the profileOrganizer.minFastPeers Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMinFastPeersMax

      public void setMinFastPeersMax(String v)
      Record the Max control for the profileOrganizer.minFastPeers Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMinFastPeersMin

      public void setMinFastPeersMin(String v)
      Record the Min control for the profileOrganizer.minFastPeers Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMinFastPeersOverride

      public void setMinFastPeersOverride(String v)
      Record the Override control for the profileOrganizer.minFastPeers Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMinFastPeersStep

      public void setMinFastPeersStep(String v)
      Record the Step control for the profileOrganizer.minFastPeers Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMinHighCapPeersDefault

      public void setMinHighCapPeersDefault(String v)
      Record the Default control for the profileOrganizer.minHighCapacityPeers Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMinHighCapPeersMax

      public void setMinHighCapPeersMax(String v)
      Record the Max control for the profileOrganizer.minHighCapacityPeers Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMinHighCapPeersMin

      public void setMinHighCapPeersMin(String v)
      Record the Min control for the profileOrganizer.minHighCapacityPeers Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMinHighCapPeersStep

      public void setMinHighCapPeersStep(String v)
      Record the Step control for the profileOrganizer.minHighCapacityPeers Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMinResendDelayDefault

      public void setMinResendDelayDefault(String v)
      Record the Default control for the i2p.streaming.minResendDelay Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMinResendDelayOverride

      public void setMinResendDelayOverride(String v)
      Record the Override control for the i2p.streaming.minResendDelay Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMlkemPrecalcMinDefault

      public void setMlkemPrecalcMinDefault(String v)
      Record the Default control for the crypto.mlkem.precalcMin Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMlkemPrecalcMinMax

      public void setMlkemPrecalcMinMax(String v)
      Record the Max control for the crypto.mlkem.precalcMin Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMlkemPrecalcMinMin

      public void setMlkemPrecalcMinMin(String v)
      Record the Min control for the crypto.mlkem.precalcMin Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMlkemPrecalcMinOverride

      public void setMlkemPrecalcMinOverride(String v)
      Record the Override control for the crypto.mlkem.precalcMin Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMlkemPrecalcMinStep

      public void setMlkemPrecalcMinStep(String v)
      Record the Step control for the crypto.mlkem.precalcMin Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNetDBMaxConcurrentDefault

      public void setNetDBMaxConcurrentDefault(String v)
      Record the Default control for the netdb.maxConcurrent Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNetDBMaxConcurrentMax

      public void setNetDBMaxConcurrentMax(String v)
      Record the Max control for the netdb.maxConcurrent Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNetDBMaxConcurrentMin

      public void setNetDBMaxConcurrentMin(String v)
      Record the Min control for the netdb.maxConcurrent Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNetDBMaxConcurrentOverride

      public void setNetDBMaxConcurrentOverride(String v)
      Record the Override control for the netdb.maxConcurrent Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNetDBMaxConcurrentStep

      public void setNetDBMaxConcurrentStep(String v)
      Record the Step control for the netdb.maxConcurrent Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNetDBSearchLimitDefault

      public void setNetDBSearchLimitDefault(String v)
      Record the Default control for the netdb.searchLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNetDBSearchLimitMax

      public void setNetDBSearchLimitMax(String v)
      Record the Max control for the netdb.searchLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNetDBSearchLimitMin

      public void setNetDBSearchLimitMin(String v)
      Record the Min control for the netdb.searchLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNetDBSearchLimitOverride

      public void setNetDBSearchLimitOverride(String v)
      Record the Override control for the netdb.searchLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNetDBSearchLimitStep

      public void setNetDBSearchLimitStep(String v)
      Record the Step control for the netdb.searchLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNetDBSingleSearchTimeDefault

      public void setNetDBSingleSearchTimeDefault(String v)
      Record the Default control for the netdb.singleSearchTime Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNetDBSingleSearchTimeMax

      public void setNetDBSingleSearchTimeMax(String v)
      Record the Max control for the netdb.singleSearchTime Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNetDBSingleSearchTimeMin

      public void setNetDBSingleSearchTimeMin(String v)
      Record the Min control for the netdb.singleSearchTime Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNetDBSingleSearchTimeOverride

      public void setNetDBSingleSearchTimeOverride(String v)
      Record the Override control for the netdb.singleSearchTime Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNetDBSingleSearchTimeStep

      public void setNetDBSingleSearchTimeStep(String v)
      Record the Step control for the netdb.singleSearchTime Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNtcpQueueCapacityDefault

      public void setNtcpQueueCapacityDefault(String v)
      Record the Default control for the ntcp.sendFinisher.queueCapacity Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNtcpQueueCapacityMax

      public void setNtcpQueueCapacityMax(String v)
      Record the Max control for the ntcp.sendFinisher.queueCapacity Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNtcpQueueCapacityMin

      public void setNtcpQueueCapacityMin(String v)
      Record the Min control for the ntcp.sendFinisher.queueCapacity Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNtcpQueueCapacityOverride

      public void setNtcpQueueCapacityOverride(String v)
      Record the Override control for the ntcp.sendFinisher.queueCapacity Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNtcpQueueCapacityStep

      public void setNtcpQueueCapacityStep(String v)
      Record the Step control for the ntcp.sendFinisher.queueCapacity Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNtcpThreadsDefault

      public void setNtcpThreadsDefault(String v)
      Record the Default control for the ntcp.sendFinisher.threads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNtcpThreadsMax

      public void setNtcpThreadsMax(String v)
      Record the Max control for the ntcp.sendFinisher.threads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNtcpThreadsMin

      public void setNtcpThreadsMin(String v)
      Record the Min control for the ntcp.sendFinisher.threads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNtcpThreadsOverride

      public void setNtcpThreadsOverride(String v)
      Record the Override control for the ntcp.sendFinisher.threads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNtcpThreadsStep

      public void setNtcpThreadsStep(String v)
      Record the Step control for the ntcp.sendFinisher.threads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setObEstablishTimeDefault

      public void setObEstablishTimeDefault(String v)
      Record the Default control for the MAX_OB_ESTABLISH_TIME Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setObEstablishTimeMax

      public void setObEstablishTimeMax(String v)
      Record the Max control for the MAX_OB_ESTABLISH_TIME Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setObEstablishTimeMin

      public void setObEstablishTimeMin(String v)
      Record the Min control for the MAX_OB_ESTABLISH_TIME Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setObEstablishTimeOverride

      public void setObEstablishTimeOverride(String v)
      Record the Override control for the MAX_OB_ESTABLISH_TIME Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setObEstablishTimeStep

      public void setObEstablishTimeStep(String v)
      Record the Step control for the MAX_OB_ESTABLISH_TIME Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setObMsgsPerPumpDefault

      public void setObMsgsPerPumpDefault(String v)
      Record the Default control for the MAX_OB_MSGS_PER_PUMP Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setObMsgsPerPumpMax

      public void setObMsgsPerPumpMax(String v)
      Record the Max control for the MAX_OB_MSGS_PER_PUMP Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setObMsgsPerPumpMin

      public void setObMsgsPerPumpMin(String v)
      Record the Min control for the MAX_OB_MSGS_PER_PUMP Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setObMsgsPerPumpOverride

      public void setObMsgsPerPumpOverride(String v)
      Record the Override control for the MAX_OB_MSGS_PER_PUMP Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setObMsgsPerPumpStep

      public void setObMsgsPerPumpStep(String v)
      Record the Step control for the MAX_OB_MSGS_PER_PUMP Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setPassiveFlushDelayDefault

      public void setPassiveFlushDelayDefault(String v)
      Record the Default control for the PASSIVE_FLUSH_DELAY Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setPassiveFlushDelayMax

      public void setPassiveFlushDelayMax(String v)
      Record the Max control for the PASSIVE_FLUSH_DELAY Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setPassiveFlushDelayMin

      public void setPassiveFlushDelayMin(String v)
      Record the Min control for the PASSIVE_FLUSH_DELAY Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setPassiveFlushDelayOverride

      public void setPassiveFlushDelayOverride(String v)
      Record the Override control for the PASSIVE_FLUSH_DELAY Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setPassiveFlushDelayStep

      public void setPassiveFlushDelayStep(String v)
      Record the Step control for the PASSIVE_FLUSH_DELAY Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setPeerOutboundQueueDefault

      public void setPeerOutboundQueueDefault(String v)
      Record the Default control for the router.peerOutboundQueueSize Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setPeerOutboundQueueMax

      public void setPeerOutboundQueueMax(String v)
      Record the Max control for the router.peerOutboundQueueSize Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setPeerOutboundQueueMin

      public void setPeerOutboundQueueMin(String v)
      Record the Min control for the router.peerOutboundQueueSize Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setPeerOutboundQueueOverride

      public void setPeerOutboundQueueOverride(String v)
      Record the Override control for the router.peerOutboundQueueSize Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setPeerOutboundQueueStep

      public void setPeerOutboundQueueStep(String v)
      Record the Step control for the router.peerOutboundQueueSize Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setPerTunnelBweDivisorDefault

      public void setPerTunnelBweDivisorDefault(String v)
      Record the Default control for the router.tunnel.perTunnelBweDivisor Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setPerTunnelBweDivisorMax

      public void setPerTunnelBweDivisorMax(String v)
      Record the Max control for the router.tunnel.perTunnelBweDivisor Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setPerTunnelBweDivisorMin

      public void setPerTunnelBweDivisorMin(String v)
      Record the Min control for the router.tunnel.perTunnelBweDivisor Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setPerTunnelBweDivisorOverride

      public void setPerTunnelBweDivisorOverride(String v)
      Record the Override control for the router.tunnel.perTunnelBweDivisor Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setPerTunnelBweDivisorStep

      public void setPerTunnelBweDivisorStep(String v)
      Record the Step control for the router.tunnel.perTunnelBweDivisor Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setReplenishFrequencyDefault

      public void setReplenishFrequencyDefault(String v)
      Record the Default control for the REPLENISH_FREQUENCY Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setReplenishFrequencyMax

      public void setReplenishFrequencyMax(String v)
      Record the Max control for the REPLENISH_FREQUENCY Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setReplenishFrequencyMin

      public void setReplenishFrequencyMin(String v)
      Record the Min control for the REPLENISH_FREQUENCY Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setReplenishFrequencyOverride

      public void setReplenishFrequencyOverride(String v)
      Record the Override control for the REPLENISH_FREQUENCY Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setReplenishFrequencyStep

      public void setReplenishFrequencyStep(String v)
      Record the Step control for the REPLENISH_FREQUENCY Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setRequeueTimeDefault

      public void setRequeueTimeDefault(String v)
      Record the Default control for the REQUEUE_TIME Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setRequeueTimeMax

      public void setRequeueTimeMax(String v)
      Record the Max control for the REQUEUE_TIME Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setRequeueTimeMin

      public void setRequeueTimeMin(String v)
      Record the Min control for the REQUEUE_TIME Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setRequeueTimeOverride

      public void setRequeueTimeOverride(String v)
      Record the Override control for the REQUEUE_TIME Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setRequeueTimeStep

      public void setRequeueTimeStep(String v)
      Record the Step control for the REQUEUE_TIME Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setSelectorLoopDelayDefault

      public void setSelectorLoopDelayDefault(String v)
      Record the Default control for the SELECTOR_LOOP_DELAY Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setSelectorLoopDelayMax

      public void setSelectorLoopDelayMax(String v)
      Record the Max control for the SELECTOR_LOOP_DELAY Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setSelectorLoopDelayMin

      public void setSelectorLoopDelayMin(String v)
      Record the Min control for the SELECTOR_LOOP_DELAY Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setSelectorLoopDelayOverride

      public void setSelectorLoopDelayOverride(String v)
      Record the Override control for the SELECTOR_LOOP_DELAY Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setSelectorLoopDelayStep

      public void setSelectorLoopDelayStep(String v)
      Record the Step control for the SELECTOR_LOOP_DELAY Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setSlowStartGrowthDefault

      public void setSlowStartGrowthDefault(String v)
      Record the Default control for the i2p.streaming.slowStartGrowthRateFactor Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setSlowStartGrowthOverride

      public void setSlowStartGrowthOverride(String v)
      Record the Override control for the i2p.streaming.slowStartGrowthRateFactor Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setThreadsDefault

      public void setThreadsDefault(String v)
      Record the Default control for the i2ptunnel.serverHandler.threads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setThreadsMax

      public void setThreadsMax(String v)
      Record the Max control for the i2ptunnel.serverHandler.threads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setThreadsMin

      public void setThreadsMin(String v)
      Record the Min control for the i2ptunnel.serverHandler.threads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setThreadsOverride

      public void setThreadsOverride(String v)
      Record the Override control for the i2ptunnel.serverHandler.threads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setThreadsStep

      public void setThreadsStep(String v)
      Record the Step control for the i2ptunnel.serverHandler.threads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setServerBacklogQueueDefault

      public void setServerBacklogQueueDefault(String v)
      Record the Default control for the i2ptunnel.serverHandler.queueCapacity Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setServerBacklogQueueMax

      public void setServerBacklogQueueMax(String v)
      Record the Max control for the i2ptunnel.serverHandler.queueCapacity Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setServerBacklogQueueMin

      public void setServerBacklogQueueMin(String v)
      Record the Min control for the i2ptunnel.serverHandler.queueCapacity Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setServerBacklogQueueOverride

      public void setServerBacklogQueueOverride(String v)
      Record the Override control for the i2ptunnel.serverHandler.queueCapacity Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setServerBacklogQueueStep

      public void setServerBacklogQueueStep(String v)
      Record the Step control for the i2ptunnel.serverHandler.queueCapacity Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setServerThreadsDefault

      public void setServerThreadsDefault(String v)
      Record the Default control for the i2ptunnel.server.threads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setServerThreadsMax

      public void setServerThreadsMax(String v)
      Record the Max control for the i2ptunnel.server.threads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setServerThreadsMin

      public void setServerThreadsMin(String v)
      Record the Min control for the i2ptunnel.server.threads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setServerThreadsOverride

      public void setServerThreadsOverride(String v)
      Record the Override control for the i2ptunnel.server.threads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setServerThreadsStep

      public void setServerThreadsStep(String v)
      Record the Step control for the i2ptunnel.server.threads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setThrottleRejectExponentDefault

      public void setThrottleRejectExponentDefault(String v)
      Record the Default control for the router.throttleRejectExponent Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setThrottleRejectExponentMax

      public void setThrottleRejectExponentMax(String v)
      Record the Max control for the router.throttleRejectExponent Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setThrottleRejectExponentMin

      public void setThrottleRejectExponentMin(String v)
      Record the Min control for the router.throttleRejectExponent Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setThrottleRejectExponentOverride

      public void setThrottleRejectExponentOverride(String v)
      Record the Override control for the router.throttleRejectExponent Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setThrottleRejectExponentStep

      public void setThrottleRejectExponentStep(String v)
      Record the Step control for the router.throttleRejectExponent Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTransitThrottleFactorDefault

      public void setTransitThrottleFactorDefault(String v)
      Record the Default control for the router.transitThrottleFactor Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTransitThrottleFactorMax

      public void setTransitThrottleFactorMax(String v)
      Record the Max control for the router.transitThrottleFactor Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTransitThrottleFactorMin

      public void setTransitThrottleFactorMin(String v)
      Record the Min control for the router.transitThrottleFactor Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTransitThrottleFactorOverride

      public void setTransitThrottleFactorOverride(String v)
      Record the Override control for the router.transitThrottleFactor Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTransitThrottleFactorStep

      public void setTransitThrottleFactorStep(String v)
      Record the Step control for the router.transitThrottleFactor Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelGrowthFactorDefault

      public void setTunnelGrowthFactorDefault(String v)
      Record the Default control for the router.tunnelGrowthFactor Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelGrowthFactorMax

      public void setTunnelGrowthFactorMax(String v)
      Record the Max control for the router.tunnelGrowthFactor Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelGrowthFactorMin

      public void setTunnelGrowthFactorMin(String v)
      Record the Min control for the router.tunnelGrowthFactor Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelGrowthFactorOverride

      public void setTunnelGrowthFactorOverride(String v)
      Record the Override control for the router.tunnelGrowthFactor Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelGrowthFactorStep

      public void setTunnelGrowthFactorStep(String v)
      Record the Step control for the router.tunnelGrowthFactor Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpHandlerThreadsDefault

      public void setUdpHandlerThreadsDefault(String v)
      Record the Default control for the udp.packetHandler.maxThreads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpHandlerThreadsMax

      public void setUdpHandlerThreadsMax(String v)
      Record the Max control for the udp.packetHandler.maxThreads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpHandlerThreadsMin

      public void setUdpHandlerThreadsMin(String v)
      Record the Min control for the udp.packetHandler.maxThreads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpHandlerThreadsOverride

      public void setUdpHandlerThreadsOverride(String v)
      Record the Override control for the udp.packetHandler.maxThreads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpHandlerThreadsStep

      public void setUdpHandlerThreadsStep(String v)
      Record the Step control for the udp.packetHandler.maxThreads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setWestwoodDecayFactorDefault

      public void setWestwoodDecayFactorDefault(String v)
      Record the Default control for the WESTWOOD_DECAY_FACTOR Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setWestwoodDecayFactorMax

      public void setWestwoodDecayFactorMax(String v)
      Record the Max control for the WESTWOOD_DECAY_FACTOR Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setWestwoodDecayFactorMin

      public void setWestwoodDecayFactorMin(String v)
      Record the Min control for the WESTWOOD_DECAY_FACTOR Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setWestwoodDecayFactorOverride

      public void setWestwoodDecayFactorOverride(String v)
      Record the Override control for the WESTWOOD_DECAY_FACTOR Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setWestwoodDecayFactorStep

      public void setWestwoodDecayFactorStep(String v)
      Record the Step control for the WESTWOOD_DECAY_FACTOR Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setWriterQueueSizeDefault

      public void setWriterQueueSizeDefault(String v)
      Record the Default control for the CLIENT_WRITER_QUEUE_SIZE Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setWriterQueueSizeMax

      public void setWriterQueueSizeMax(String v)
      Record the Max control for the CLIENT_WRITER_QUEUE_SIZE Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setWriterQueueSizeMin

      public void setWriterQueueSizeMin(String v)
      Record the Min control for the CLIENT_WRITER_QUEUE_SIZE Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setWriterQueueSizeOverride

      public void setWriterQueueSizeOverride(String v)
      Record the Override control for the CLIENT_WRITER_QUEUE_SIZE Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setWriterQueueSizeStep

      public void setWriterQueueSizeStep(String v)
      Record the Step control for the CLIENT_WRITER_QUEUE_SIZE Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setXdhPreCalcMinDefault

      public void setXdhPreCalcMinDefault(String v)
      Record the Default control for the crypto.x25519.precalcMin Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setXdhPreCalcMinMax

      public void setXdhPreCalcMinMax(String v)
      Record the Max control for the crypto.x25519.precalcMin Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setXdhPreCalcMinMin

      public void setXdhPreCalcMinMin(String v)
      Record the Min control for the crypto.x25519.precalcMin Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setXdhPreCalcMinOverride

      public void setXdhPreCalcMinOverride(String v)
      Record the Override control for the crypto.x25519.precalcMin Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setXdhPreCalcMinStep

      public void setXdhPreCalcMinStep(String v)
      Record the Step control for the crypto.x25519.precalcMin Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setConnectTimeoutMultiplierDefault

      public void setConnectTimeoutMultiplierDefault(String v)
      Record the Default control for the CONNECT_TIMEOUT_MULTIPLIER Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setConnectTimeoutMultiplierMax

      public void setConnectTimeoutMultiplierMax(String v)
      Record the Max control for the CONNECT_TIMEOUT_MULTIPLIER Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setConnectTimeoutMultiplierMin

      public void setConnectTimeoutMultiplierMin(String v)
      Record the Min control for the CONNECT_TIMEOUT_MULTIPLIER Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setConnectTimeoutMultiplierOverride

      public void setConnectTimeoutMultiplierOverride(String v)
      Record the Override control for the CONNECT_TIMEOUT_MULTIPLIER Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setConnectTimeoutMultiplierStep

      public void setConnectTimeoutMultiplierStep(String v)
      Record the Step control for the CONNECT_TIMEOUT_MULTIPLIER Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2cpInternalqueuesizeDefault

      public void setI2cpInternalqueuesizeDefault(String v)
      Record the Default control for the i2cp.internalQueueSize Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2cpInternalqueuesizeMax

      public void setI2cpInternalqueuesizeMax(String v)
      Record the Max control for the i2cp.internalQueueSize Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2cpInternalqueuesizeMin

      public void setI2cpInternalqueuesizeMin(String v)
      Record the Min control for the i2cp.internalQueueSize Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2cpInternalqueuesizeOverride

      public void setI2cpInternalqueuesizeOverride(String v)
      Record the Override control for the i2cp.internalQueueSize Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2cpInternalqueuesizeStep

      public void setI2cpInternalqueuesizeStep(String v)
      Record the Step control for the i2cp.internalQueueSize Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pRouterHandlerthreadpriorityDefault

      public void setI2pRouterHandlerthreadpriorityDefault(String v)
      Record the Default control for the i2p.router.handlerThreadPriority Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pRouterHandlerthreadpriorityMax

      public void setI2pRouterHandlerthreadpriorityMax(String v)
      Record the Max control for the i2p.router.handlerThreadPriority Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pRouterHandlerthreadpriorityMin

      public void setI2pRouterHandlerthreadpriorityMin(String v)
      Record the Min control for the i2p.router.handlerThreadPriority Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pRouterHandlerthreadpriorityOverride

      public void setI2pRouterHandlerthreadpriorityOverride(String v)
      Record the Override control for the i2p.router.handlerThreadPriority Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pRouterHandlerthreadpriorityStep

      public void setI2pRouterHandlerthreadpriorityStep(String v)
      Record the Step control for the i2p.router.handlerThreadPriority Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pRouterMaxdispatchageDefault

      public void setI2pRouterMaxdispatchageDefault(String v)
      Record the Default control for the i2p.router.maxDispatchAge Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pRouterMaxdispatchageMax

      public void setI2pRouterMaxdispatchageMax(String v)
      Record the Max control for the i2p.router.maxDispatchAge Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pRouterMaxdispatchageMin

      public void setI2pRouterMaxdispatchageMin(String v)
      Record the Min control for the i2p.router.maxDispatchAge Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pRouterMaxdispatchageOverride

      public void setI2pRouterMaxdispatchageOverride(String v)
      Record the Override control for the i2p.router.maxDispatchAge Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pRouterMaxdispatchageStep

      public void setI2pRouterMaxdispatchageStep(String v)
      Record the Step control for the i2p.router.maxDispatchAge Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pStreamingInactivitytimeoutDefault

      public void setI2pStreamingInactivitytimeoutDefault(String v)
      Record the Default control for the i2p.streaming.inactivityTimeout Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pStreamingInactivitytimeoutMax

      public void setI2pStreamingInactivitytimeoutMax(String v)
      Record the Max control for the i2p.streaming.inactivityTimeout Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pStreamingInactivitytimeoutMin

      public void setI2pStreamingInactivitytimeoutMin(String v)
      Record the Min control for the i2p.streaming.inactivityTimeout Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pStreamingInactivitytimeoutOverride

      public void setI2pStreamingInactivitytimeoutOverride(String v)
      Record the Override control for the i2p.streaming.inactivityTimeout Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pStreamingInactivitytimeoutStep

      public void setI2pStreamingInactivitytimeoutStep(String v)
      Record the Step control for the i2p.streaming.inactivityTimeout Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pStreamingMaxsynresendsDefault

      public void setI2pStreamingMaxsynresendsDefault(String v)
      Record the Default control for the i2p.streaming.maxSynResends Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pStreamingMaxsynresendsMax

      public void setI2pStreamingMaxsynresendsMax(String v)
      Record the Max control for the i2p.streaming.maxSynResends Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pStreamingMaxsynresendsMin

      public void setI2pStreamingMaxsynresendsMin(String v)
      Record the Min control for the i2p.streaming.maxSynResends Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pStreamingMaxsynresendsOverride

      public void setI2pStreamingMaxsynresendsOverride(String v)
      Record the Override control for the i2p.streaming.maxSynResends Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pStreamingMaxsynresendsStep

      public void setI2pStreamingMaxsynresendsStep(String v)
      Record the Step control for the i2p.streaming.maxSynResends Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pStreamingMaxwindowsizeDefault

      public void setI2pStreamingMaxwindowsizeDefault(String v)
      Record the Default control for the i2p.streaming.maxWindowSize Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pStreamingMaxwindowsizeMax

      public void setI2pStreamingMaxwindowsizeMax(String v)
      Record the Max control for the i2p.streaming.maxWindowSize Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pStreamingMaxwindowsizeMin

      public void setI2pStreamingMaxwindowsizeMin(String v)
      Record the Min control for the i2p.streaming.maxWindowSize Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pStreamingMaxwindowsizeOverride

      public void setI2pStreamingMaxwindowsizeOverride(String v)
      Record the Override control for the i2p.streaming.maxWindowSize Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pStreamingMaxwindowsizeStep

      public void setI2pStreamingMaxwindowsizeStep(String v)
      Record the Step control for the i2p.streaming.maxWindowSize Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pStreamingMinpacingrateDefault

      public void setI2pStreamingMinpacingrateDefault(String v)
      Record the Default control for the i2p.streaming.minPacingRate Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pStreamingMinpacingrateMax

      public void setI2pStreamingMinpacingrateMax(String v)
      Record the Max control for the i2p.streaming.minPacingRate Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pStreamingMinpacingrateMin

      public void setI2pStreamingMinpacingrateMin(String v)
      Record the Min control for the i2p.streaming.minPacingRate Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pStreamingMinpacingrateOverride

      public void setI2pStreamingMinpacingrateOverride(String v)
      Record the Override control for the i2p.streaming.minPacingRate Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pStreamingMinpacingrateStep

      public void setI2pStreamingMinpacingrateStep(String v)
      Record the Step control for the i2p.streaming.minPacingRate Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pStreamingRtomultiplierDefault

      public void setI2pStreamingRtomultiplierDefault(String v)
      Record the Default control for the i2p.streaming.rtoMultiplier Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pStreamingRtomultiplierMax

      public void setI2pStreamingRtomultiplierMax(String v)
      Record the Max control for the i2p.streaming.rtoMultiplier Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pStreamingRtomultiplierMin

      public void setI2pStreamingRtomultiplierMin(String v)
      Record the Min control for the i2p.streaming.rtoMultiplier Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pStreamingRtomultiplierOverride

      public void setI2pStreamingRtomultiplierOverride(String v)
      Record the Override control for the i2p.streaming.rtoMultiplier Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pStreamingRtomultiplierStep

      public void setI2pStreamingRtomultiplierStep(String v)
      Record the Step control for the i2p.streaming.rtoMultiplier Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelBuildMaxlookuplimitDefault

      public void setI2pTunnelBuildMaxlookuplimitDefault(String v)
      Record the Default control for the i2p.tunnel.build.maxLookupLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelBuildMaxlookuplimitMax

      public void setI2pTunnelBuildMaxlookuplimitMax(String v)
      Record the Max control for the i2p.tunnel.build.maxLookupLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelBuildMaxlookuplimitMin

      public void setI2pTunnelBuildMaxlookuplimitMin(String v)
      Record the Min control for the i2p.tunnel.build.maxLookupLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelBuildMaxlookuplimitOverride

      public void setI2pTunnelBuildMaxlookuplimitOverride(String v)
      Record the Override control for the i2p.tunnel.build.maxLookupLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelBuildMaxlookuplimitStep

      public void setI2pTunnelBuildMaxlookuplimitStep(String v)
      Record the Step control for the i2p.tunnel.build.maxLookupLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelBuildPercentlookuplimitDefault

      public void setI2pTunnelBuildPercentlookuplimitDefault(String v)
      Record the Default control for the i2p.tunnel.build.percentLookupLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelBuildPercentlookuplimitMax

      public void setI2pTunnelBuildPercentlookuplimitMax(String v)
      Record the Max control for the i2p.tunnel.build.percentLookupLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelBuildPercentlookuplimitMin

      public void setI2pTunnelBuildPercentlookuplimitMin(String v)
      Record the Min control for the i2p.tunnel.build.percentLookupLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelBuildPercentlookuplimitOverride

      public void setI2pTunnelBuildPercentlookuplimitOverride(String v)
      Record the Override control for the i2p.tunnel.build.percentLookupLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelBuildPercentlookuplimitStep

      public void setI2pTunnelBuildPercentlookuplimitStep(String v)
      Record the Step control for the i2p.tunnel.build.percentLookupLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleLoadweightDefault

      public void setI2pTunnelParticipatingthrottleLoadweightDefault(String v)
      Record the Default control for the i2p.tunnel.participatingThrottle.loadWeight Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleLoadweightMax

      public void setI2pTunnelParticipatingthrottleLoadweightMax(String v)
      Record the Max control for the i2p.tunnel.participatingThrottle.loadWeight Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleLoadweightMin

      public void setI2pTunnelParticipatingthrottleLoadweightMin(String v)
      Record the Min control for the i2p.tunnel.participatingThrottle.loadWeight Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleLoadweightOverride

      public void setI2pTunnelParticipatingthrottleLoadweightOverride(String v)
      Record the Override control for the i2p.tunnel.participatingThrottle.loadWeight Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelParticipatingthrottleLoadweightStep

      public void setI2pTunnelParticipatingthrottleLoadweightStep(String v)
      Record the Step control for the i2p.tunnel.participatingThrottle.loadWeight Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleMaxlimitDefault

      public void setI2pTunnelParticipatingthrottleMaxlimitDefault(String v)
      Record the Default control for the i2p.tunnel.participatingThrottle.maxLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleMaxlimitMax

      public void setI2pTunnelParticipatingthrottleMaxlimitMax(String v)
      Record the Max control for the i2p.tunnel.participatingThrottle.maxLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleMaxlimitMin

      public void setI2pTunnelParticipatingthrottleMaxlimitMin(String v)
      Record the Min control for the i2p.tunnel.participatingThrottle.maxLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleMaxlimitOverride

      public void setI2pTunnelParticipatingthrottleMaxlimitOverride(String v)
      Record the Override control for the i2p.tunnel.participatingThrottle.maxLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelParticipatingthrottleMaxlimitStep

      public void setI2pTunnelParticipatingthrottleMaxlimitStep(String v)
      Record the Step control for the i2p.tunnel.participatingThrottle.maxLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleMinlimitDefault

      public void setI2pTunnelParticipatingthrottleMinlimitDefault(String v)
      Record the Default control for the i2p.tunnel.participatingThrottle.minLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleMinlimitMax

      public void setI2pTunnelParticipatingthrottleMinlimitMax(String v)
      Record the Max control for the i2p.tunnel.participatingThrottle.minLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleMinlimitMin

      public void setI2pTunnelParticipatingthrottleMinlimitMin(String v)
      Record the Min control for the i2p.tunnel.participatingThrottle.minLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleMinlimitOverride

      public void setI2pTunnelParticipatingthrottleMinlimitOverride(String v)
      Record the Override control for the i2p.tunnel.participatingThrottle.minLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelParticipatingthrottleMinlimitStep

      public void setI2pTunnelParticipatingthrottleMinlimitStep(String v)
      Record the Step control for the i2p.tunnel.participatingThrottle.minLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelParticipatingthrottlePercentlimitDefault

      public void setI2pTunnelParticipatingthrottlePercentlimitDefault(String v)
      Record the Default control for the i2p.tunnel.participatingThrottle.percentLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelParticipatingthrottlePercentlimitMax

      public void setI2pTunnelParticipatingthrottlePercentlimitMax(String v)
      Record the Max control for the i2p.tunnel.participatingThrottle.percentLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelParticipatingthrottlePercentlimitMin

      public void setI2pTunnelParticipatingthrottlePercentlimitMin(String v)
      Record the Min control for the i2p.tunnel.participatingThrottle.percentLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelParticipatingthrottlePercentlimitOverride

      public void setI2pTunnelParticipatingthrottlePercentlimitOverride(String v)
      Record the Override control for the i2p.tunnel.participatingThrottle.percentLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelParticipatingthrottlePercentlimitStep

      public void setI2pTunnelParticipatingthrottlePercentlimitStep(String v)
      Record the Step control for the i2p.tunnel.participatingThrottle.percentLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleRejectsteepnessDefault

      public void setI2pTunnelParticipatingthrottleRejectsteepnessDefault(String v)
      Record the Default control for the i2p.tunnel.participatingThrottle.rejectSteepness Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleRejectsteepnessMax

      public void setI2pTunnelParticipatingthrottleRejectsteepnessMax(String v)
      Record the Max control for the i2p.tunnel.participatingThrottle.rejectSteepness Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleRejectsteepnessMin

      public void setI2pTunnelParticipatingthrottleRejectsteepnessMin(String v)
      Record the Min control for the i2p.tunnel.participatingThrottle.rejectSteepness Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleRejectsteepnessOverride

      public void setI2pTunnelParticipatingthrottleRejectsteepnessOverride(String v)
      Record the Override control for the i2p.tunnel.participatingThrottle.rejectSteepness Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelParticipatingthrottleRejectsteepnessStep

      public void setI2pTunnelParticipatingthrottleRejectsteepnessStep(String v)
      Record the Step control for the i2p.tunnel.participatingThrottle.rejectSteepness Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleRejectthresholdDefault

      public void setI2pTunnelParticipatingthrottleRejectthresholdDefault(String v)
      Record the Default control for the i2p.tunnel.participatingThrottle.rejectThreshold Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleRejectthresholdMax

      public void setI2pTunnelParticipatingthrottleRejectthresholdMax(String v)
      Record the Max control for the i2p.tunnel.participatingThrottle.rejectThreshold Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleRejectthresholdMin

      public void setI2pTunnelParticipatingthrottleRejectthresholdMin(String v)
      Record the Min control for the i2p.tunnel.participatingThrottle.rejectThreshold Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelParticipatingthrottleRejectthresholdOverride

      public void setI2pTunnelParticipatingthrottleRejectthresholdOverride(String v)
      Record the Override control for the i2p.tunnel.participatingThrottle.rejectThreshold Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelParticipatingthrottleRejectthresholdStep

      public void setI2pTunnelParticipatingthrottleRejectthresholdStep(String v)
      Record the Step control for the i2p.tunnel.participatingThrottle.rejectThreshold Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleBurst1sthresholdDefault

      public void setI2pTunnelRequestthrottleBurst1sthresholdDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.burst1sThreshold Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleBurst1sthresholdMax

      public void setI2pTunnelRequestthrottleBurst1sthresholdMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.burst1sThreshold Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleBurst1sthresholdMin

      public void setI2pTunnelRequestthrottleBurst1sthresholdMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.burst1sThreshold Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleBurst1sthresholdOverride

      public void setI2pTunnelRequestthrottleBurst1sthresholdOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.burst1sThreshold Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleBurst1sthresholdStep

      public void setI2pTunnelRequestthrottleBurst1sthresholdStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.burst1sThreshold Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleHighloadcpupctDefault

      public void setI2pTunnelRequestthrottleHighloadcpupctDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.highLoadCpuPct Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleHighloadcpupctMax

      public void setI2pTunnelRequestthrottleHighloadcpupctMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.highLoadCpuPct Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleHighloadcpupctMin

      public void setI2pTunnelRequestthrottleHighloadcpupctMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.highLoadCpuPct Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleHighloadcpupctOverride

      public void setI2pTunnelRequestthrottleHighloadcpupctOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.highLoadCpuPct Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleHighloadcpupctStep

      public void setI2pTunnelRequestthrottleHighloadcpupctStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.highLoadCpuPct Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleHighloadlagmsDefault

      public void setI2pTunnelRequestthrottleHighloadlagmsDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.highLoadLagMs Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleHighloadlagmsMax

      public void setI2pTunnelRequestthrottleHighloadlagmsMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.highLoadLagMs Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleHighloadlagmsMin

      public void setI2pTunnelRequestthrottleHighloadlagmsMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.highLoadLagMs Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleHighloadlagmsOverride

      public void setI2pTunnelRequestthrottleHighloadlagmsOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.highLoadLagMs Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleHighloadlagmsStep

      public void setI2pTunnelRequestthrottleHighloadlagmsStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.highLoadLagMs Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleLoadweightDefault

      public void setI2pTunnelRequestthrottleLoadweightDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.loadWeight Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleLoadweightMax

      public void setI2pTunnelRequestthrottleLoadweightMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.loadWeight Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleLoadweightMin

      public void setI2pTunnelRequestthrottleLoadweightMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.loadWeight Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleLoadweightOverride

      public void setI2pTunnelRequestthrottleLoadweightOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.loadWeight Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleLoadweightStep

      public void setI2pTunnelRequestthrottleLoadweightStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.loadWeight Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleMaxlimitDefault

      public void setI2pTunnelRequestthrottleMaxlimitDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.maxLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleMaxlimitMax

      public void setI2pTunnelRequestthrottleMaxlimitMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.maxLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleMaxlimitMin

      public void setI2pTunnelRequestthrottleMaxlimitMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.maxLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleMaxlimitOverride

      public void setI2pTunnelRequestthrottleMaxlimitOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.maxLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleMaxlimitStep

      public void setI2pTunnelRequestthrottleMaxlimitStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.maxLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleMinlimitDefault

      public void setI2pTunnelRequestthrottleMinlimitDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.minLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleMinlimitMax

      public void setI2pTunnelRequestthrottleMinlimitMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.minLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleMinlimitMin

      public void setI2pTunnelRequestthrottleMinlimitMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.minLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleMinlimitOverride

      public void setI2pTunnelRequestthrottleMinlimitOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.minLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleMinlimitStep

      public void setI2pTunnelRequestthrottleMinlimitStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.minLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleModerateloadcpupctDefault

      public void setI2pTunnelRequestthrottleModerateloadcpupctDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.moderateLoadCpuPct Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleModerateloadcpupctMax

      public void setI2pTunnelRequestthrottleModerateloadcpupctMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.moderateLoadCpuPct Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleModerateloadcpupctMin

      public void setI2pTunnelRequestthrottleModerateloadcpupctMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.moderateLoadCpuPct Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleModerateloadcpupctOverride

      public void setI2pTunnelRequestthrottleModerateloadcpupctOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.moderateLoadCpuPct Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleModerateloadcpupctStep

      public void setI2pTunnelRequestthrottleModerateloadcpupctStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.moderateLoadCpuPct Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleModerateloadlagmsDefault

      public void setI2pTunnelRequestthrottleModerateloadlagmsDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.moderateLoadLagMs Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleModerateloadlagmsMax

      public void setI2pTunnelRequestthrottleModerateloadlagmsMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.moderateLoadLagMs Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleModerateloadlagmsMin

      public void setI2pTunnelRequestthrottleModerateloadlagmsMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.moderateLoadLagMs Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleModerateloadlagmsOverride

      public void setI2pTunnelRequestthrottleModerateloadlagmsOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.moderateLoadLagMs Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleModerateloadlagmsStep

      public void setI2pTunnelRequestthrottleModerateloadlagmsStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.moderateLoadLagMs Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottlePercentlimitDefault

      public void setI2pTunnelRequestthrottlePercentlimitDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.percentLimit Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottlePercentlimitMax

      public void setI2pTunnelRequestthrottlePercentlimitMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.percentLimit Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottlePercentlimitMin

      public void setI2pTunnelRequestthrottlePercentlimitMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.percentLimit Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottlePercentlimitOverride

      public void setI2pTunnelRequestthrottlePercentlimitOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.percentLimit Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottlePercentlimitStep

      public void setI2pTunnelRequestthrottlePercentlimitStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.percentLimit Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleRejectsteepnessDefault

      public void setI2pTunnelRequestthrottleRejectsteepnessDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.rejectSteepness Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleRejectsteepnessMax

      public void setI2pTunnelRequestthrottleRejectsteepnessMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.rejectSteepness Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleRejectsteepnessMin

      public void setI2pTunnelRequestthrottleRejectsteepnessMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.rejectSteepness Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleRejectsteepnessOverride

      public void setI2pTunnelRequestthrottleRejectsteepnessOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.rejectSteepness Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleRejectsteepnessStep

      public void setI2pTunnelRequestthrottleRejectsteepnessStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.rejectSteepness Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleRejectthresholdDefault

      public void setI2pTunnelRequestthrottleRejectthresholdDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.rejectThreshold Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleRejectthresholdMax

      public void setI2pTunnelRequestthrottleRejectthresholdMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.rejectThreshold Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleRejectthresholdMin

      public void setI2pTunnelRequestthrottleRejectthresholdMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.rejectThreshold Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleRejectthresholdOverride

      public void setI2pTunnelRequestthrottleRejectthresholdOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.rejectThreshold Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleRejectthresholdStep

      public void setI2pTunnelRequestthrottleRejectthresholdStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.rejectThreshold Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelRequestthrottleSustainedhighloadmsDefault

      public void setI2pTunnelRequestthrottleSustainedhighloadmsDefault(String v)
      Record the Default control submitted under the i2pTunnelRequestthrottleSustainedhighloadms form prefix. No Tuner param carries that prefix, so TUNED holds no entry for it and processForm() never consumes the value.
      Parameters:
      v - raw Default input text, never read
    • setI2pTunnelRequestthrottleSustainedhighloadmsMax

      public void setI2pTunnelRequestthrottleSustainedhighloadmsMax(String v)
      Record the Max control submitted under the i2pTunnelRequestthrottleSustainedhighloadms form prefix. No Tuner param carries that prefix, so TUNED holds no entry for it and processForm() never consumes the value.
      Parameters:
      v - raw Max input text, never read
    • setI2pTunnelRequestthrottleSustainedhighloadmsMin

      public void setI2pTunnelRequestthrottleSustainedhighloadmsMin(String v)
      Record the Min control submitted under the i2pTunnelRequestthrottleSustainedhighloadms form prefix. No Tuner param carries that prefix, so TUNED holds no entry for it and processForm() never consumes the value.
      Parameters:
      v - raw Min input text, never read
    • setI2pTunnelRequestthrottleSustainedhighloadmsOverride

      public void setI2pTunnelRequestthrottleSustainedhighloadmsOverride(String v)
      Record the Override control submitted under the i2pTunnelRequestthrottleSustainedhighloadms form prefix. No Tuner param carries that prefix, so TUNED holds no entry for it and processForm() never consumes the value.
      Parameters:
      v - raw Override input text, never read
    • setI2pTunnelRequestthrottleSustainedhighloadmsStep

      public void setI2pTunnelRequestthrottleSustainedhighloadmsStep(String v)
      Record the Step control submitted under the i2pTunnelRequestthrottleSustainedhighloadms form prefix. No Tuner param carries that prefix, so TUNED holds no entry for it and processForm() never consumes the value.
      Parameters:
      v - raw Step input text, never read
    • setI2pTunnelRequestthrottleSustainedmoderateloadmsDefault

      public void setI2pTunnelRequestthrottleSustainedmoderateloadmsDefault(String v)
      Record the Default control for the i2p.tunnel.requestThrottle.sustainedModerateLoadMs Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelRequestthrottleSustainedmoderateloadmsMax

      public void setI2pTunnelRequestthrottleSustainedmoderateloadmsMax(String v)
      Record the Max control for the i2p.tunnel.requestThrottle.sustainedModerateLoadMs Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelRequestthrottleSustainedmoderateloadmsMin

      public void setI2pTunnelRequestthrottleSustainedmoderateloadmsMin(String v)
      Record the Min control for the i2p.tunnel.requestThrottle.sustainedModerateLoadMs Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelRequestthrottleSustainedmoderateloadmsOverride

      public void setI2pTunnelRequestthrottleSustainedmoderateloadmsOverride(String v)
      Record the Override control for the i2p.tunnel.requestThrottle.sustainedModerateLoadMs Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelRequestthrottleSustainedmoderateloadmsStep

      public void setI2pTunnelRequestthrottleSustainedmoderateloadmsStep(String v)
      Record the Step control for the i2p.tunnel.requestThrottle.sustainedModerateLoadMs Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelSocketconnecttimeoutDefault

      public void setI2pTunnelSocketconnecttimeoutDefault(String v)
      Record the Default control for the i2p.tunnel.socketConnectTimeout Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelSocketconnecttimeoutMax

      public void setI2pTunnelSocketconnecttimeoutMax(String v)
      Record the Max control for the i2p.tunnel.socketConnectTimeout Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelSocketconnecttimeoutMin

      public void setI2pTunnelSocketconnecttimeoutMin(String v)
      Record the Min control for the i2p.tunnel.socketConnectTimeout Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelSocketconnecttimeoutOverride

      public void setI2pTunnelSocketconnecttimeoutOverride(String v)
      Record the Override control for the i2p.tunnel.socketConnectTimeout Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelSocketconnecttimeoutStep

      public void setI2pTunnelSocketconnecttimeoutStep(String v)
      Record the Step control for the i2p.tunnel.socketConnectTimeout Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelTargetbufferDefault

      public void setI2pTunnelTargetbufferDefault(String v)
      Record the Default control for the i2p.tunnel.targetBuffer Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelTargetbufferMax

      public void setI2pTunnelTargetbufferMax(String v)
      Record the Max control for the i2p.tunnel.targetBuffer Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelTargetbufferMin

      public void setI2pTunnelTargetbufferMin(String v)
      Record the Min control for the i2p.tunnel.targetBuffer Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelTargetbufferOverride

      public void setI2pTunnelTargetbufferOverride(String v)
      Record the Override control for the i2p.tunnel.targetBuffer Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelTargetbufferStep

      public void setI2pTunnelTargetbufferStep(String v)
      Record the Step control for the i2p.tunnel.targetBuffer Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2pTunnelUntestedmultiplierDefault

      public void setI2pTunnelUntestedmultiplierDefault(String v)
      Record the Default control for the i2p.tunnel.untestedMultiplier Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2pTunnelUntestedmultiplierMax

      public void setI2pTunnelUntestedmultiplierMax(String v)
      Record the Max control for the i2p.tunnel.untestedMultiplier Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2pTunnelUntestedmultiplierMin

      public void setI2pTunnelUntestedmultiplierMin(String v)
      Record the Min control for the i2p.tunnel.untestedMultiplier Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2pTunnelUntestedmultiplierOverride

      public void setI2pTunnelUntestedmultiplierOverride(String v)
      Record the Override control for the i2p.tunnel.untestedMultiplier Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2pTunnelUntestedmultiplierStep

      public void setI2pTunnelUntestedmultiplierStep(String v)
      Record the Step control for the i2p.tunnel.untestedMultiplier Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setI2ptunnelClientrunnerMaxDefault

      public void setI2ptunnelClientrunnerMaxDefault(String v)
      Record the Default control for the i2ptunnel.clientRunner.max Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setI2ptunnelClientrunnerMaxMax

      public void setI2ptunnelClientrunnerMaxMax(String v)
      Record the Max control for the i2ptunnel.clientRunner.max Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setI2ptunnelClientrunnerMaxMin

      public void setI2ptunnelClientrunnerMaxMin(String v)
      Record the Min control for the i2ptunnel.clientRunner.max Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setI2ptunnelClientrunnerMaxOverride

      public void setI2ptunnelClientrunnerMaxOverride(String v)
      Record the Override control for the i2ptunnel.clientRunner.max Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setI2ptunnelClientrunnerMaxStep

      public void setI2ptunnelClientrunnerMaxStep(String v)
      Record the Step control for the i2ptunnel.clientRunner.max Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxLsLookupTimeDefault

      public void setMaxLsLookupTimeDefault(String v)
      Record the Default control for the MAX_LS_LOOKUP_TIME Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxLsLookupTimeMax

      public void setMaxLsLookupTimeMax(String v)
      Record the Max control for the MAX_LS_LOOKUP_TIME Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxLsLookupTimeMin

      public void setMaxLsLookupTimeMin(String v)
      Record the Min control for the MAX_LS_LOOKUP_TIME Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxLsLookupTimeOverride

      public void setMaxLsLookupTimeOverride(String v)
      Record the Override control for the MAX_LS_LOOKUP_TIME Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxLsLookupTimeStep

      public void setMaxLsLookupTimeStep(String v)
      Record the Step control for the MAX_LS_LOOKUP_TIME Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setMaxRiLookupTimeDefault

      public void setMaxRiLookupTimeDefault(String v)
      Record the Default control for the MAX_RI_LOOKUP_TIME Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setMaxRiLookupTimeMax

      public void setMaxRiLookupTimeMax(String v)
      Record the Max control for the MAX_RI_LOOKUP_TIME Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setMaxRiLookupTimeMin

      public void setMaxRiLookupTimeMin(String v)
      Record the Min control for the MAX_RI_LOOKUP_TIME Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setMaxRiLookupTimeOverride

      public void setMaxRiLookupTimeOverride(String v)
      Record the Override control for the MAX_RI_LOOKUP_TIME Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setMaxRiLookupTimeStep

      public void setMaxRiLookupTimeStep(String v)
      Record the Step control for the MAX_RI_LOOKUP_TIME Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNtcpEstablishTimeoutDefault

      public void setNtcpEstablishTimeoutDefault(String v)
      Record the Default control for the NTCP_ESTABLISH_TIMEOUT Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNtcpEstablishTimeoutMax

      public void setNtcpEstablishTimeoutMax(String v)
      Record the Max control for the NTCP_ESTABLISH_TIMEOUT Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNtcpEstablishTimeoutMin

      public void setNtcpEstablishTimeoutMin(String v)
      Record the Min control for the NTCP_ESTABLISH_TIMEOUT Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNtcpEstablishTimeoutOverride

      public void setNtcpEstablishTimeoutOverride(String v)
      Record the Override control for the NTCP_ESTABLISH_TIMEOUT Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNtcpEstablishTimeoutStep

      public void setNtcpEstablishTimeoutStep(String v)
      Record the Step control for the NTCP_ESTABLISH_TIMEOUT Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNtcpFailsafeIterationfreqDefault

      public void setNtcpFailsafeIterationfreqDefault(String v)
      Record the Default control for the ntcp.failsafe.iterationFreq Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNtcpFailsafeIterationfreqMax

      public void setNtcpFailsafeIterationfreqMax(String v)
      Record the Max control for the ntcp.failsafe.iterationFreq Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNtcpFailsafeIterationfreqMin

      public void setNtcpFailsafeIterationfreqMin(String v)
      Record the Min control for the ntcp.failsafe.iterationFreq Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNtcpFailsafeIterationfreqOverride

      public void setNtcpFailsafeIterationfreqOverride(String v)
      Record the Override control for the ntcp.failsafe.iterationFreq Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNtcpFailsafeIterationfreqStep

      public void setNtcpFailsafeIterationfreqStep(String v)
      Record the Step control for the ntcp.failsafe.iterationFreq Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNtcpMaxwritebufsDefault

      public void setNtcpMaxwritebufsDefault(String v)
      Record the Default control for the ntcp.maxWriteBufs Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNtcpMaxwritebufsMax

      public void setNtcpMaxwritebufsMax(String v)
      Record the Max control for the ntcp.maxWriteBufs Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNtcpMaxwritebufsMin

      public void setNtcpMaxwritebufsMin(String v)
      Record the Min control for the ntcp.maxWriteBufs Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNtcpMaxwritebufsOverride

      public void setNtcpMaxwritebufsOverride(String v)
      Record the Override control for the ntcp.maxWriteBufs Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNtcpMaxwritebufsStep

      public void setNtcpMaxwritebufsStep(String v)
      Record the Step control for the ntcp.maxWriteBufs Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNtcpReaderThreadsDefault

      public void setNtcpReaderThreadsDefault(String v)
      Record the Default control for the ntcp.reader.threads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNtcpReaderThreadsMax

      public void setNtcpReaderThreadsMax(String v)
      Record the Max control for the ntcp.reader.threads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNtcpReaderThreadsMin

      public void setNtcpReaderThreadsMin(String v)
      Record the Min control for the ntcp.reader.threads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNtcpReaderThreadsOverride

      public void setNtcpReaderThreadsOverride(String v)
      Record the Override control for the ntcp.reader.threads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNtcpReaderThreadsStep

      public void setNtcpReaderThreadsStep(String v)
      Record the Step control for the ntcp.reader.threads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNtcpSendpoolCapacityDefault

      public void setNtcpSendpoolCapacityDefault(String v)
      Record the Default control for the ntcp.sendPool.capacity Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNtcpSendpoolCapacityMax

      public void setNtcpSendpoolCapacityMax(String v)
      Record the Max control for the ntcp.sendPool.capacity Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNtcpSendpoolCapacityMin

      public void setNtcpSendpoolCapacityMin(String v)
      Record the Min control for the ntcp.sendPool.capacity Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNtcpSendpoolCapacityOverride

      public void setNtcpSendpoolCapacityOverride(String v)
      Record the Override control for the ntcp.sendPool.capacity Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNtcpSendpoolCapacityStep

      public void setNtcpSendpoolCapacityStep(String v)
      Record the Step control for the ntcp.sendPool.capacity Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setNtcpWriterThreadsDefault

      public void setNtcpWriterThreadsDefault(String v)
      Record the Default control for the ntcp.writer.threads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setNtcpWriterThreadsMax

      public void setNtcpWriterThreadsMax(String v)
      Record the Max control for the ntcp.writer.threads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setNtcpWriterThreadsMin

      public void setNtcpWriterThreadsMin(String v)
      Record the Min control for the ntcp.writer.threads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setNtcpWriterThreadsOverride

      public void setNtcpWriterThreadsOverride(String v)
      Record the Override control for the ntcp.writer.threads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setNtcpWriterThreadsStep

      public void setNtcpWriterThreadsStep(String v)
      Record the Step control for the ntcp.writer.threads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setRdnsCorepoolsizeDefault

      public void setRdnsCorepoolsizeDefault(String v)
      Record the Default control for the rdns.corePoolSize Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setRdnsCorepoolsizeMax

      public void setRdnsCorepoolsizeMax(String v)
      Record the Max control for the rdns.corePoolSize Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setRdnsCorepoolsizeMin

      public void setRdnsCorepoolsizeMin(String v)
      Record the Min control for the rdns.corePoolSize Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setRdnsCorepoolsizeOverride

      public void setRdnsCorepoolsizeOverride(String v)
      Record the Override control for the rdns.corePoolSize Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setRdnsCorepoolsizeStep

      public void setRdnsCorepoolsizeStep(String v)
      Record the Step control for the rdns.corePoolSize Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setRedMaxDropProbDefault

      public void setRedMaxDropProbDefault(String v)
      Record the Default control for the RED_MAX_DROP_PROB Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setRedMaxDropProbMax

      public void setRedMaxDropProbMax(String v)
      Record the Max control for the RED_MAX_DROP_PROB Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setRedMaxDropProbMin

      public void setRedMaxDropProbMin(String v)
      Record the Min control for the RED_MAX_DROP_PROB Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setRedMaxDropProbOverride

      public void setRedMaxDropProbOverride(String v)
      Record the Override control for the RED_MAX_DROP_PROB Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setRedMaxDropProbStep

      public void setRedMaxDropProbStep(String v)
      Record the Step control for the RED_MAX_DROP_PROB Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setRedMaxThresholdDefault

      public void setRedMaxThresholdDefault(String v)
      Record the Default control for the RED_MAX_THRESHOLD Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setRedMaxThresholdMax

      public void setRedMaxThresholdMax(String v)
      Record the Max control for the RED_MAX_THRESHOLD Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setRedMaxThresholdMin

      public void setRedMaxThresholdMin(String v)
      Record the Min control for the RED_MAX_THRESHOLD Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setRedMaxThresholdOverride

      public void setRedMaxThresholdOverride(String v)
      Record the Override control for the RED_MAX_THRESHOLD Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setRedMaxThresholdStep

      public void setRedMaxThresholdStep(String v)
      Record the Step control for the RED_MAX_THRESHOLD Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setRedMinThresholdDefault

      public void setRedMinThresholdDefault(String v)
      Record the Default control for the RED_MIN_THRESHOLD Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setRedMinThresholdMax

      public void setRedMinThresholdMax(String v)
      Record the Max control for the RED_MIN_THRESHOLD Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setRedMinThresholdMin

      public void setRedMinThresholdMin(String v)
      Record the Min control for the RED_MIN_THRESHOLD Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setRedMinThresholdOverride

      public void setRedMinThresholdOverride(String v)
      Record the Override control for the RED_MIN_THRESHOLD Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setRedMinThresholdStep

      public void setRedMinThresholdStep(String v)
      Record the Step control for the RED_MIN_THRESHOLD Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setRouterBuildhandlerthreadsDefault

      public void setRouterBuildhandlerthreadsDefault(String v)
      Record the Default control for the router.buildHandlerThreads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setRouterBuildhandlerthreadsMax

      public void setRouterBuildhandlerthreadsMax(String v)
      Record the Max control for the router.buildHandlerThreads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setRouterBuildhandlerthreadsMin

      public void setRouterBuildhandlerthreadsMin(String v)
      Record the Min control for the router.buildHandlerThreads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setRouterBuildhandlerthreadsOverride

      public void setRouterBuildhandlerthreadsOverride(String v)
      Record the Override control for the router.buildHandlerThreads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setRouterBuildhandlerthreadsStep

      public void setRouterBuildhandlerthreadsStep(String v)
      Record the Step control for the router.buildHandlerThreads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setRouterDefaultprocessingtimethrottleDefault

      public void setRouterDefaultprocessingtimethrottleDefault(String v)
      Record the Default control for the router.defaultProcessingTimeThrottle Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setRouterDefaultprocessingtimethrottleMax

      public void setRouterDefaultprocessingtimethrottleMax(String v)
      Record the Max control for the router.defaultProcessingTimeThrottle Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setRouterDefaultprocessingtimethrottleMin

      public void setRouterDefaultprocessingtimethrottleMin(String v)
      Record the Min control for the router.defaultProcessingTimeThrottle Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setRouterDefaultprocessingtimethrottleOverride

      public void setRouterDefaultprocessingtimethrottleOverride(String v)
      Record the Override control for the router.defaultProcessingTimeThrottle Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setRouterDefaultprocessingtimethrottleStep

      public void setRouterDefaultprocessingtimethrottleStep(String v)
      Record the Step control for the router.defaultProcessingTimeThrottle Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelBuildMaxconcurrentDefault

      public void setTunnelBuildMaxconcurrentDefault(String v)
      Record the Default control for the tunnel.build.maxConcurrent Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelBuildMaxconcurrentMax

      public void setTunnelBuildMaxconcurrentMax(String v)
      Record the Max control for the tunnel.build.maxConcurrent Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelBuildMaxconcurrentMin

      public void setTunnelBuildMaxconcurrentMin(String v)
      Record the Min control for the tunnel.build.maxConcurrent Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelBuildMaxconcurrentOverride

      public void setTunnelBuildMaxconcurrentOverride(String v)
      Record the Override control for the tunnel.build.maxConcurrent Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelBuildMaxconcurrentStep

      public void setTunnelBuildMaxconcurrentStep(String v)
      Record the Step control for the tunnel.build.maxConcurrent Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelPeerselectionActivitywindowmultiplierDefault

      public void setTunnelPeerselectionActivitywindowmultiplierDefault(String v)
      Record the Default control for the tunnel.peerSelection.activityWindowMultiplier Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelPeerselectionActivitywindowmultiplierMax

      public void setTunnelPeerselectionActivitywindowmultiplierMax(String v)
      Record the Max control for the tunnel.peerSelection.activityWindowMultiplier Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelPeerselectionActivitywindowmultiplierMin

      public void setTunnelPeerselectionActivitywindowmultiplierMin(String v)
      Record the Min control for the tunnel.peerSelection.activityWindowMultiplier Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelPeerselectionActivitywindowmultiplierOverride

      public void setTunnelPeerselectionActivitywindowmultiplierOverride(String v)
      Record the Override control for the tunnel.peerSelection.activityWindowMultiplier Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelPeerselectionActivitywindowmultiplierStep

      public void setTunnelPeerselectionActivitywindowmultiplierStep(String v)
      Record the Step control for the tunnel.peerSelection.activityWindowMultiplier Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelPoolBackoffmsDefault

      public void setTunnelPoolBackoffmsDefault(String v)
      Record the Default control for the tunnel.pool.backoffMs Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelPoolBackoffmsMax

      public void setTunnelPoolBackoffmsMax(String v)
      Record the Max control for the tunnel.pool.backoffMs Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelPoolBackoffmsMin

      public void setTunnelPoolBackoffmsMin(String v)
      Record the Min control for the tunnel.pool.backoffMs Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelPoolBackoffmsOverride

      public void setTunnelPoolBackoffmsOverride(String v)
      Record the Override control for the tunnel.pool.backoffMs Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelPoolBackoffmsStep

      public void setTunnelPoolBackoffmsStep(String v)
      Record the Step control for the tunnel.pool.backoffMs Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelPoolFailurethresholdDefault

      public void setTunnelPoolFailurethresholdDefault(String v)
      Record the Default control for the tunnel.pool.failureThreshold Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelPoolFailurethresholdMax

      public void setTunnelPoolFailurethresholdMax(String v)
      Record the Max control for the tunnel.pool.failureThreshold Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelPoolFailurethresholdMin

      public void setTunnelPoolFailurethresholdMin(String v)
      Record the Min control for the tunnel.pool.failureThreshold Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelPoolFailurethresholdOverride

      public void setTunnelPoolFailurethresholdOverride(String v)
      Record the Override control for the tunnel.pool.failureThreshold Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelPoolFailurethresholdStep

      public void setTunnelPoolFailurethresholdStep(String v)
      Record the Step control for the tunnel.pool.failureThreshold Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelPumperQueuecapacityDefault

      public void setTunnelPumperQueuecapacityDefault(String v)
      Record the Default control for the tunnel.pumper.queueCapacity Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelPumperQueuecapacityMax

      public void setTunnelPumperQueuecapacityMax(String v)
      Record the Max control for the tunnel.pumper.queueCapacity Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelPumperQueuecapacityMin

      public void setTunnelPumperQueuecapacityMin(String v)
      Record the Min control for the tunnel.pumper.queueCapacity Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelPumperQueuecapacityOverride

      public void setTunnelPumperQueuecapacityOverride(String v)
      Record the Override control for the tunnel.pumper.queueCapacity Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelPumperQueuecapacityStep

      public void setTunnelPumperQueuecapacityStep(String v)
      Record the Step control for the tunnel.pumper.queueCapacity Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelPumperThreadsDefault

      public void setTunnelPumperThreadsDefault(String v)
      Record the Default control for the tunnel.pumper.threads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelPumperThreadsMax

      public void setTunnelPumperThreadsMax(String v)
      Record the Max control for the tunnel.pumper.threads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelPumperThreadsMin

      public void setTunnelPumperThreadsMin(String v)
      Record the Min control for the tunnel.pumper.threads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelPumperThreadsOverride

      public void setTunnelPumperThreadsOverride(String v)
      Record the Override control for the tunnel.pumper.threads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelPumperThreadsStep

      public void setTunnelPumperThreadsStep(String v)
      Record the Step control for the tunnel.pumper.threads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelTestjobMaxqueuedDefault

      public void setTunnelTestjobMaxqueuedDefault(String v)
      Record the Default control for the tunnel.testJob.maxQueued Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelTestjobMaxqueuedMax

      public void setTunnelTestjobMaxqueuedMax(String v)
      Record the Max control for the tunnel.testJob.maxQueued Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelTestjobMaxqueuedMin

      public void setTunnelTestjobMaxqueuedMin(String v)
      Record the Min control for the tunnel.testJob.maxQueued Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelTestjobMaxqueuedOverride

      public void setTunnelTestjobMaxqueuedOverride(String v)
      Record the Override control for the tunnel.testJob.maxQueued Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelTestjobMaxqueuedStep

      public void setTunnelTestjobMaxqueuedStep(String v)
      Record the Step control for the tunnel.testJob.maxQueued Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelTestjobMaxtestdelayDefault

      public void setTunnelTestjobMaxtestdelayDefault(String v)
      Record the Default control for the tunnel.testJob.maxTestDelay Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelTestjobMaxtestdelayMax

      public void setTunnelTestjobMaxtestdelayMax(String v)
      Record the Max control for the tunnel.testJob.maxTestDelay Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelTestjobMaxtestdelayMin

      public void setTunnelTestjobMaxtestdelayMin(String v)
      Record the Min control for the tunnel.testJob.maxTestDelay Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelTestjobMaxtestdelayOverride

      public void setTunnelTestjobMaxtestdelayOverride(String v)
      Record the Override control for the tunnel.testJob.maxTestDelay Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelTestjobMaxtestdelayStep

      public void setTunnelTestjobMaxtestdelayStep(String v)
      Record the Step control for the tunnel.testJob.maxTestDelay Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelTestjobMintestdelayDefault

      public void setTunnelTestjobMintestdelayDefault(String v)
      Record the Default control for the tunnel.testJob.minTestDelay Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelTestjobMintestdelayMax

      public void setTunnelTestjobMintestdelayMax(String v)
      Record the Max control for the tunnel.testJob.minTestDelay Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelTestjobMintestdelayMin

      public void setTunnelTestjobMintestdelayMin(String v)
      Record the Min control for the tunnel.testJob.minTestDelay Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelTestjobMintestdelayOverride

      public void setTunnelTestjobMintestdelayOverride(String v)
      Record the Override control for the tunnel.testJob.minTestDelay Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelTestjobMintestdelayStep

      public void setTunnelTestjobMintestdelayStep(String v)
      Record the Step control for the tunnel.testJob.minTestDelay Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelTestjobMaxtestperiodDefault

      public void setTunnelTestjobMaxtestperiodDefault(String v)
      Record the Default control for the i2p.tunnel.testJob.maxTestPeriod Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelTestjobMaxtestperiodMax

      public void setTunnelTestjobMaxtestperiodMax(String v)
      Record the Max control for the i2p.tunnel.testJob.maxTestPeriod Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelTestjobMaxtestperiodMin

      public void setTunnelTestjobMaxtestperiodMin(String v)
      Record the Min control for the i2p.tunnel.testJob.maxTestPeriod Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelTestjobMaxtestperiodOverride

      public void setTunnelTestjobMaxtestperiodOverride(String v)
      Record the Override control for the i2p.tunnel.testJob.maxTestPeriod Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelTestjobMaxtestperiodStep

      public void setTunnelTestjobMaxtestperiodStep(String v)
      Record the Step control for the i2p.tunnel.testJob.maxTestPeriod Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setTunnelTestjobMintestperiodDefault

      public void setTunnelTestjobMintestperiodDefault(String v)
      Record the Default control for the i2p.tunnel.testJob.minTestPeriod Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setTunnelTestjobMintestperiodMax

      public void setTunnelTestjobMintestperiodMax(String v)
      Record the Max control for the i2p.tunnel.testJob.minTestPeriod Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setTunnelTestjobMintestperiodMin

      public void setTunnelTestjobMintestperiodMin(String v)
      Record the Min control for the i2p.tunnel.testJob.minTestPeriod Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setTunnelTestjobMintestperiodOverride

      public void setTunnelTestjobMintestperiodOverride(String v)
      Record the Override control for the i2p.tunnel.testJob.minTestPeriod Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setTunnelTestjobMintestperiodStep

      public void setTunnelTestjobMintestperiodStep(String v)
      Record the Step control for the i2p.tunnel.testJob.minTestPeriod Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpEstablishMaxqueuedoutboundDefault

      public void setUdpEstablishMaxqueuedoutboundDefault(String v)
      Record the Default control for the udp.establish.maxQueuedOutbound Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpEstablishMaxqueuedoutboundMax

      public void setUdpEstablishMaxqueuedoutboundMax(String v)
      Record the Max control for the udp.establish.maxQueuedOutbound Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpEstablishMaxqueuedoutboundMin

      public void setUdpEstablishMaxqueuedoutboundMin(String v)
      Record the Min control for the udp.establish.maxQueuedOutbound Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpEstablishMaxqueuedoutboundOverride

      public void setUdpEstablishMaxqueuedoutboundOverride(String v)
      Record the Override control for the udp.establish.maxQueuedOutbound Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpEstablishMaxqueuedoutboundStep

      public void setUdpEstablishMaxqueuedoutboundStep(String v)
      Record the Step control for the udp.establish.maxQueuedOutbound Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpMessagereceiverThreadsDefault

      public void setUdpMessagereceiverThreadsDefault(String v)
      Record the Default control for the udp.messageReceiver.threads Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpMessagereceiverThreadsMax

      public void setUdpMessagereceiverThreadsMax(String v)
      Record the Max control for the udp.messageReceiver.threads Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpMessagereceiverThreadsMin

      public void setUdpMessagereceiverThreadsMin(String v)
      Record the Min control for the udp.messageReceiver.threads Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpMessagereceiverThreadsOverride

      public void setUdpMessagereceiverThreadsOverride(String v)
      Record the Override control for the udp.messageReceiver.threads Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpMessagereceiverThreadsStep

      public void setUdpMessagereceiverThreadsStep(String v)
      Record the Step control for the udp.messageReceiver.threads Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerConcurrentmaxmessagesDefault

      public void setUdpPeerConcurrentmaxmessagesDefault(String v)
      Record the Default control for the udp.peer.concurrentMaxMessages Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerConcurrentmaxmessagesMax

      public void setUdpPeerConcurrentmaxmessagesMax(String v)
      Record the Max control for the udp.peer.concurrentMaxMessages Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerConcurrentmaxmessagesMin

      public void setUdpPeerConcurrentmaxmessagesMin(String v)
      Record the Min control for the udp.peer.concurrentMaxMessages Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerConcurrentmaxmessagesOverride

      public void setUdpPeerConcurrentmaxmessagesOverride(String v)
      Record the Override control for the udp.peer.concurrentMaxMessages Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerConcurrentmaxmessagesStep

      public void setUdpPeerConcurrentmaxmessagesStep(String v)
      Record the Step control for the udp.peer.concurrentMaxMessages Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerInitconcurrentmsgsDefault

      public void setUdpPeerInitconcurrentmsgsDefault(String v)
      Record the Default control for the udp.peer.initConcurrentMsgs Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerInitconcurrentmsgsMax

      public void setUdpPeerInitconcurrentmsgsMax(String v)
      Record the Max control for the udp.peer.initConcurrentMsgs Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerInitconcurrentmsgsMin

      public void setUdpPeerInitconcurrentmsgsMin(String v)
      Record the Min control for the udp.peer.initConcurrentMsgs Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerInitconcurrentmsgsOverride

      public void setUdpPeerInitconcurrentmsgsOverride(String v)
      Record the Override control for the udp.peer.initConcurrentMsgs Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerInitconcurrentmsgsStep

      public void setUdpPeerInitconcurrentmsgsStep(String v)
      Record the Step control for the udp.peer.initConcurrentMsgs Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerInitrtoDefault

      public void setUdpPeerInitrtoDefault(String v)
      Record the Default control for the udp.peer.initRTO Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerInitrtoMax

      public void setUdpPeerInitrtoMax(String v)
      Record the Max control for the udp.peer.initRTO Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerInitrtoMin

      public void setUdpPeerInitrtoMin(String v)
      Record the Min control for the udp.peer.initRTO Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerInitrtoOverride

      public void setUdpPeerInitrtoOverride(String v)
      Record the Override control for the udp.peer.initRTO Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerInitrtoStep

      public void setUdpPeerInitrtoStep(String v)
      Record the Step control for the udp.peer.initRTO Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerMaxrtoDefault

      public void setUdpPeerMaxrtoDefault(String v)
      Record the Default control for the udp.peer.maxRTO Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerMaxrtoMax

      public void setUdpPeerMaxrtoMax(String v)
      Record the Max control for the udp.peer.maxRTO Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerMaxrtoMin

      public void setUdpPeerMaxrtoMin(String v)
      Record the Min control for the udp.peer.maxRTO Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerMaxrtoOverride

      public void setUdpPeerMaxrtoOverride(String v)
      Record the Override control for the udp.peer.maxRTO Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerMaxrtoStep

      public void setUdpPeerMaxrtoStep(String v)
      Record the Step control for the udp.peer.maxRTO Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerMaxsendwindowDefault

      public void setUdpPeerMaxsendwindowDefault(String v)
      Record the Default control for the udp.peer.maxSendWindow Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerMaxsendwindowMax

      public void setUdpPeerMaxsendwindowMax(String v)
      Record the Max control for the udp.peer.maxSendWindow Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerMaxsendwindowMin

      public void setUdpPeerMaxsendwindowMin(String v)
      Record the Min control for the udp.peer.maxSendWindow Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerMaxsendwindowOverride

      public void setUdpPeerMaxsendwindowOverride(String v)
      Record the Override control for the udp.peer.maxSendWindow Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerMaxsendwindowStep

      public void setUdpPeerMaxsendwindowStep(String v)
      Record the Step control for the udp.peer.maxSendWindow Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerMinconcurrentmsgsDefault

      public void setUdpPeerMinconcurrentmsgsDefault(String v)
      Record the Default control for the udp.peer.minConcurrentMsgs Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerMinconcurrentmsgsMax

      public void setUdpPeerMinconcurrentmsgsMax(String v)
      Record the Max control for the udp.peer.minConcurrentMsgs Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerMinconcurrentmsgsMin

      public void setUdpPeerMinconcurrentmsgsMin(String v)
      Record the Min control for the udp.peer.minConcurrentMsgs Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerMinconcurrentmsgsOverride

      public void setUdpPeerMinconcurrentmsgsOverride(String v)
      Record the Override control for the udp.peer.minConcurrentMsgs Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerMinconcurrentmsgsStep

      public void setUdpPeerMinconcurrentmsgsStep(String v)
      Record the Step control for the udp.peer.minConcurrentMsgs Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerMinrtoDefault

      public void setUdpPeerMinrtoDefault(String v)
      Record the Default control for the udp.peer.minRTO Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerMinrtoMax

      public void setUdpPeerMinrtoMax(String v)
      Record the Max control for the udp.peer.minRTO Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerMinrtoMin

      public void setUdpPeerMinrtoMin(String v)
      Record the Min control for the udp.peer.minRTO Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerMinrtoOverride

      public void setUdpPeerMinrtoOverride(String v)
      Record the Override control for the udp.peer.minRTO Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerMinrtoStep

      public void setUdpPeerMinrtoStep(String v)
      Record the Step control for the udp.peer.minRTO Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerOutboundmsgexpirationDefault

      public void setUdpPeerOutboundmsgexpirationDefault(String v)
      Record the Default control for the udp.peer.outboundMsgExpiration Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerOutboundmsgexpirationMax

      public void setUdpPeerOutboundmsgexpirationMax(String v)
      Record the Max control for the udp.peer.outboundMsgExpiration Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerOutboundmsgexpirationMin

      public void setUdpPeerOutboundmsgexpirationMin(String v)
      Record the Min control for the udp.peer.outboundMsgExpiration Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerOutboundmsgexpirationOverride

      public void setUdpPeerOutboundmsgexpirationOverride(String v)
      Record the Override control for the udp.peer.outboundMsgExpiration Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerOutboundmsgexpirationStep

      public void setUdpPeerOutboundmsgexpirationStep(String v)
      Record the Step control for the udp.peer.outboundMsgExpiration Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerPostrtowindowmtusDefault

      public void setUdpPeerPostrtowindowmtusDefault(String v)
      Record the Default control for the udp.peer.postRTOWindowMTUs Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerPostrtowindowmtusMax

      public void setUdpPeerPostrtowindowmtusMax(String v)
      Record the Max control for the udp.peer.postRTOWindowMTUs Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerPostrtowindowmtusMin

      public void setUdpPeerPostrtowindowmtusMin(String v)
      Record the Min control for the udp.peer.postRTOWindowMTUs Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerPostrtowindowmtusOverride

      public void setUdpPeerPostrtowindowmtusOverride(String v)
      Record the Override control for the udp.peer.postRTOWindowMTUs Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerPostrtowindowmtusStep

      public void setUdpPeerPostrtowindowmtusStep(String v)
      Record the Step control for the udp.peer.postRTOWindowMTUs Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • setUdpPeerSentmessagescleantimeDefault

      public void setUdpPeerSentmessagescleantimeDefault(String v)
      Record the Default control for the udp.peer.sentMessagesCleanTime Tuner param: the default the auto-tuner starts from and reverts toward.
      Parameters:
      v - raw text from the Default input, parsed by saveField()
    • setUdpPeerSentmessagescleantimeMax

      public void setUdpPeerSentmessagescleantimeMax(String v)
      Record the Max control for the udp.peer.sentMessagesCleanTime Tuner param: the ceiling the auto-tuner will not go above.
      Parameters:
      v - raw text from the Max input, parsed by saveField()
    • setUdpPeerSentmessagescleantimeMin

      public void setUdpPeerSentmessagescleantimeMin(String v)
      Record the Min control for the udp.peer.sentMessagesCleanTime Tuner param: the floor the auto-tuner will not go below.
      Parameters:
      v - raw text from the Min input, parsed by saveField()
    • setUdpPeerSentmessagescleantimeOverride

      public void setUdpPeerSentmessagescleantimeOverride(String v)
      Record the Override control for the udp.peer.sentMessagesCleanTime Tuner param: negative resumes auto-tuning, non-negative locks a value.
      Parameters:
      v - form value: "-1" = auto, otherwise a manual lock
    • setUdpPeerSentmessagescleantimeStep

      public void setUdpPeerSentmessagescleantimeStep(String v)
      Record the Step control for the udp.peer.sentMessagesCleanTime Tuner param: the largest change the auto-tuner may apply per update.
      Parameters:
      v - raw text from the Step input, parsed by saveField()
    • getFormPrefix

      public static String getFormPrefix(String prop)
      Form-field prefix for a tunable param, used by TuningHelper to render the row's input names so they match the setters in this class. Params not listed here have no user overrides and are rendered read-only.
      Parameters:
      prop - the Tuner param name
      Returns:
      the prefix, or null if the param has no form controls
    • saveField

      private void saveField(Map<String,String> changes, String param, String field, String value)
      Save a single field if it is a valid integer.
      Parameters:
      changes - map of property key to value
      param - the tunable property name
      field - the suffix, e.g. Min, Max, Step, Default
      value - the submitted form value, or null if absent
    • applyOverride

      private void applyOverride(Tuner tuner, String paramName, String value)
      Apply an auto-tuning override.
      Parameters:
      tuner - the Tuner the override is written to
      paramName - the Tuner param name
      value - form value: "-1" = auto, numeric = manual lock
    • getTuner

      private Tuner getTuner()
      Get the Tuner instance via the UDP transport.
      Returns:
      the UDP transport's Tuner, or null if the router context, comm system, or UDP transport is not available
    • processForm

      protected void processForm()
      Description copied from class: FormHandler
      Implement this to perform the final processing (in turn, adding formNotice and formError messages, etc)

      Will only be called if _action is non-null and the nonce is valid.

      Specified by:
      processForm in class FormHandler